ThermalStandard
Package: PowerOperationsOpenAPIModels · Source: Operations/StaticInjection/ThermalStandard.json
A thermal generator, such as a fossil fuel and nuclear generator.
This is a standard representation with options to include a minimum up time, minimum down time, and ramp limits. For a more detailed representation of the start-up and shut-down processes, including hot starts, see ThermalMultiStart.
Properties
| Property | Type | Required | Unit | Description |
|---|---|---|---|---|
id | integer | yes | — | Unique integer identifier for this component. |
name | string | yes | — | Name of the component. Components of the same type (e.g., PowerLoad) must have unique names, but components of different types (e.g., PowerLoad and ACBus) can have the same name. |
available | boolean | yes | — | Indicator of whether the component is connected and online (true) or disconnected, offline, or down (false). Unavailable components are excluded during simulations. |
status | string (OperationalStates) | yes | — | Operating state of the unit at the start of a simulation. |
commitment_mode | string (CommitmentModes) | — | — | Commitment mode of the unit. |
bus | integer | yes | — | ID of the bus that this component is connected to. |
active_power | number | yes | MW / pu (by power_units) | Initial active power set point of the unit. For power flow, this is the steady state operating point of the system. For production cost modeling, this may or may not be used as the initial starting point for the solver, depending on the solver used. Units: per power_units — NATURAL_UNITS: MW, COMPONENT_BASE: pu . |
reactive_power | number | yes | MVAr / pu (by power_units) | Initial reactive power set point of the unit. Units: per power_units — NATURAL_UNITS: MVAr, COMPONENT_BASE: pu . |
rating | number | yes | MVA / pu (by power_units) | Maximum AC side output power rating of the unit. Not to be confused with base_power. Units: per power_units — NATURAL_UNITS: MVA, COMPONENT_BASE: pu . |
active_power_limits | MinMax | yes | MW / pu (by power_units) | Minimum and maximum stable active power levels. Units: per power_units — NATURAL_UNITS: MW, COMPONENT_BASE: pu . |
reactive_power_limits | MinMax | — | MVAr / pu (by power_units) | Minimum and maximum reactive power limits. Set to null if not applicable. Units: per power_units — NATURAL_UNITS: MVAr, COMPONENT_BASE: pu . |
ramp_limits | UpDown | — | MW/min / pu/min (by power_units) | Ramp up and ramp down limits. Units: per power_units — NATURAL_UNITS: MW/min, COMPONENT_BASE: pu/min . |
operation_cost | ThermalGenerationCost or MarketBidCost or MarketBidTimeSeriesCost or ImportExportTimeSeriesCost | yes | — | Operating cost of generation, or a MarketBidCost. |
base_power | number | yes | MVA | Base power of the unit for per unitization. Must be positive; a zero base would make per-unit conversion undefined. Units: MVA. |
power_units | string (UnitSystem) | yes | — | Unit basis for this component’s power-family fields (active/reactive/apparent power, ratings, limits, ramp rates). COMPONENT_BASE: per unit on this component’s own base_power. NATURAL_UNITS: the field’s physical unit. |
time_limits | UpDown | — | min | Minimum up and minimum down time limits. Units: min. |
prime_mover_type | string (PrimeMovers) | — | — | Prime mover technology according to EIA 923. |
fuel | string (ThermalFuels) | — | — | Prime mover fuel according to EIA 923. |
time_at_status | number | — | min | Time the generator has been in its current status. Units: min. |
dynamic_injector | integer or null | — | — | ID of the corresponding dynamic injection device, if any. |