HydroDispatch

Package: PowerOperationsOpenAPIModels · Source: Operations/StaticInjection/HydroDispatch.json

A hydropower generator without a reservoir, suitable for modeling run-of-river hydropower.

For hydro generators with an upper reservoir, see HydroReservoir.

Properties

Property Type Required Unit Description
id integer yes Unique integer identifier for this component.
name string yes Name of the component. Components of the same type (e.g., PowerLoad) must have unique names, but components of different types (e.g., PowerLoad and ACBus) can have the same name.
available boolean yes Indicator of whether the component is connected and online (true) or disconnected, offline, or down (false). Unavailable components are excluded during simulations.
bus integer yes ID of the bus that this component is connected to.
active_power number yes MW / pu (by power_units) Initial active power set point of the unit. For power flow, this is the steady state operating point of the system. For production cost modeling, this may or may not be used as the initial starting point for the solver, depending on the solver used. Units: per power_units — NATURAL_UNITS: MW, COMPONENT_BASE: pu .
reactive_power number yes MVAr / pu (by power_units) Initial reactive power set point of the unit. Units: per power_units — NATURAL_UNITS: MVAr, COMPONENT_BASE: pu .
rating number yes MVA / pu (by power_units) Maximum AC side output power rating of the unit. Not to be confused with base_power. Units: per power_units — NATURAL_UNITS: MVA, COMPONENT_BASE: pu .
prime_mover_type string (PrimeMovers) yes Prime mover technology according to EIA 923.
active_power_limits MinMax yes MW / pu (by power_units) Minimum and maximum stable active power levels. Units: per power_units — NATURAL_UNITS: MW, COMPONENT_BASE: pu .
reactive_power_limits MinMax MVAr / pu (by power_units) Minimum and maximum reactive power limits. Set to null if not applicable. Units: per power_units — NATURAL_UNITS: MVAr, COMPONENT_BASE: pu .
ramp_limits UpDown MW/min / pu/min (by power_units) Ramp up and ramp down limits. Units: per power_units — NATURAL_UNITS: MW/min, COMPONENT_BASE: pu/min .
time_limits UpDown min Minimum up and minimum down time limits. Units: min.
base_power number yes MVA Base power of the unit for per unitization. Units: MVA.
power_units string (UnitSystem) yes Unit basis for this component’s power-family fields (active/reactive/apparent power, ratings, limits, ramp rates). COMPONENT_BASE: per unit on this component’s own base_power. NATURAL_UNITS: the field’s physical unit.
status string (OperationalStates) Operating state of the unit at the start of a simulation.
time_at_status number min Time the generator has been in its current status. default is the INFINITE_TIME sentinel (1e4 hours, 600000 minutes). Units: min.
operation_cost HydroGenerationCost or MarketBidCost or MarketBidTimeSeriesCost or ImportExportTimeSeriesCost yes Operating cost of generation. or MarketBidCost; default PSY.HydroGenerationCost(nothing)
dynamic_injector integer or null ID of the corresponding dynamic injection device, if any.

This site uses Just the Docs, a documentation theme for Jekyll.