LoadZone

Package: PowerCoreOpenAPIModels · Source: Core/Topology/LoadZone.json

A load zone for electricity price analysis. The load zone can be specified when defining each ACBus or DCBus in the zone.

Properties

Property Type Required Unit Description
id integer yes — Unique integer identifier for this component.
name string yes — Name of the component. Components of the same type (e.g., PowerLoad) must have unique names, but components of different types (e.g., PowerLoad and ACBus) can have the same name.
peak_active_power number yes MW / pu (by power_units) Peak active power in the zone. Units: per power_units — NATURAL_UNITS: MW, COMPONENT_BASE: pu .
peak_reactive_power number yes MVAr / pu (by power_units) Peak reactive power in the zone. Units: per power_units — NATURAL_UNITS: MVAr, COMPONENT_BASE: pu .
base_power number yes MVA System base power for per-unitization of this component’s per-unit fields, recorded per component in lieu of a system-level table. Units: MVA.
power_units string (UnitSystem) yes — Unit basis for this component’s power-family fields (active/reactive/apparent power, ratings, limits, ramp rates). COMPONENT_BASE: per unit on this component’s own base_power. NATURAL_UNITS: the field’s physical unit.