SimpleMarconatoMachine

Package: PowerDynamicsOpenAPIModels · Source: Dynamics/DynamicGeneratorComponent/Machine/SimpleMarconatoMachine.json

Parameters of 4-states synchronous machine: Simplified Marconato model The derivative of stator fluxes (ψd and ψq) is neglected and ωψd = ψd and ωψq = ψq is assumed (i.e. ω=1.0). This is standard when transmission network dynamics is neglected

Properties

Property Type Required Unit Description
id integer yes — Unique integer identifier for this component
R number yes — Resistance after EMF
Xd number yes — Reactance after EMF in d-axis
Xq number yes — Reactance after EMF in q-axis
Xd_p number yes — Transient reactance after EMF in d-axis
Xq_p number yes — Transient reactance after EMF in q-axis
Xd_pp number yes — Sub-Transient reactance after EMF in d-axis
Xq_pp number yes — Sub-Transient reactance after EMF in q-axis
Td0_p number yes — Time constant of transient d-axis voltage
Tq0_p number yes — Time constant of transient q-axis voltage
Td0_pp number yes — Time constant of sub-transient d-axis voltage
Tq0_pp number yes — Time constant of sub-transient q-axis voltage
T_AA number yes — Time constant of d-axis additional leakage

This site uses Just the Docs, a documentation theme for Jekyll.