RenewableDispatch

Package: PowerOperationsOpenAPIModels · Source: Operations/StaticInjection/RenewableDispatch.json

A renewable (e.g., wind or solar) generator whose output can be curtailed to satisfy power system constraints.

These generators can also participate in reserves markets, including upwards reserves by proactively curtailing some available power (based on its max_active_power time series). Example uses include: a utility-scale wind or solar generator whose PPA allows curtailment. For non-curtailable or must-take renewables, see RenewableNonDispatch.

Renewable generators do not have a max_active_power parameter, which is instead calculated when calling get_max_active_power().

Properties

Property Type Required Unit Description
id integer yes Unique integer identifier for this component.
name string yes Name of the component. Components of the same type (e.g., PowerLoad) must have unique names, but components of different types (e.g., PowerLoad and ACBus) can have the same name.
available boolean yes Indicator of whether the component is connected and online (true) or disconnected, offline, or down (false). Unavailable components are excluded during simulations.
bus integer yes ID of the bus that this component is connected to.
active_power number yes MW / pu (by power_units) Initial active power set point of the unit. For power flow, this is the steady state operating point of the system. For production cost modeling, this may or may not be used as the initial starting point for the solver, depending on the solver used. Units: per power_units — NATURAL_UNITS: MW, COMPONENT_BASE: pu .
reactive_power number yes MVAr / pu (by power_units) Initial reactive power set point of the unit, used in some production cost modeling simulations. To set the reactive power in a load flow, use power_factor. Units: per power_units — NATURAL_UNITS: MVAr, COMPONENT_BASE: pu .
rating number yes MVA / pu (by power_units) Maximum AC side output power rating of the unit. Not to be confused with base_power. Units: per power_units — NATURAL_UNITS: MVA, COMPONENT_BASE: pu .
prime_mover_type string (PrimeMovers) yes Prime mover technology according to EIA 923.
reactive_power_limits MinMax MVAr / pu (by power_units) Minimum and maximum reactive power limits, used in some production cost model simulations and in power flow if the unit is connected to a PV bus. Set to null if not applicable. Units: per power_units — NATURAL_UNITS: MVAr, COMPONENT_BASE: pu .
power_factor number yes 1 Power factor [0, 1] set-point, used in some production cost modeling and in load flow if the unit is connected to a PQ bus. Units: 1.
operation_cost RenewableGenerationCost or MarketBidCost or MarketBidTimeSeriesCost or ImportExportTimeSeriesCost yes Operating cost of generation. or MarketBidCost
base_power number yes MVA Base power of the unit for per unitization. Units: MVA.
power_units string (UnitSystem) yes Unit basis for this component’s power-family fields (active/reactive/apparent power, ratings, limits, ramp rates). COMPONENT_BASE: per unit on this component’s own base_power. NATURAL_UNITS: the field’s physical unit.
dynamic_injector integer or null ID of the corresponding dynamic injection device, if any.